A dual fuel system pairs an electric heat pump with a gas furnace, letting your home use either heat source as conditions change. The right package depends on more than its advertised tonnage or efficiency rating.
These 10 Goodman configurations span 1.5 to 3 tons and several furnace efficiencies. Use the comparisons below to identify promising options, then have an HVAC contractor verify the sizing and installation requirements.
Best 10 Dual Fuel Furnace Systems Picks for 2026
High-Efficiency Gas Pick
Goodman 2-Ton 96% AFUE Dual-Fuel System
- 2-ton matched system rated 14.5 SEER2
- 60,000 BTU/h input, two-stage 96% AFUE furnace
- Upflow/downflow coil with factory-installed TXV
Best For: 2-ton installations prioritizing efficient, two-stage gas heat
3-Ton Balanced Pick
Goodman 15.2 SEER2 80,000 BTU Dual-Fuel System
- 3-ton matched system rated 15.2 SEER2
- 80,000 BTU/h input, single-stage 80% AFUE furnace
- Upflow/downflow coil with factory-installed TXV
Best For: 3-ton projects calling for 80,000 BTU/h gas input
Horizontal-Coil Pick
Goodman 2-Ton 92% AFUE Dual-Fuel System
- Horizontal cased coil with factory-installed TXV
- 2-ton matched system rated 14.5 SEER2
- 60,000 BTU/h input, single-stage 92% AFUE furnace
Best For: 2-ton installations requiring a horizontal coil
Higher Gas-Input Pick
Goodman 3-Ton 100,000 BTU Dual-Fuel System
- 100,000 BTU/h input, single-stage 80% AFUE furnace
- 3-ton matched system rated 15.2 SEER2
- Upflow/downflow coil with factory-installed TXV
Best For: 3-ton projects requiring 100,000 BTU/h gas input
High-Output Gas Backup
Goodman 2.5-Ton 15.2 SEER2 Dual-Fuel System
- 2.5-ton, 15.2 SEER2 matched cooling system
- 80,000 BTU/h input furnace at 96% AFUE
- Single-stage heat pump and gas heat
Best For: Professionally sized installations needing 2.5-ton cooling and 80,000 BTU/h gas input
Compact 2-Ton Match
Goodman 15.2 SEER2 Dual-Fuel System
- 2-ton, 15.2 SEER2 matched cooling system
- 60,000 BTU/h input furnace at 80% AFUE
- Upflow/downflow coil with factory TXV
Best For: Professionally sized 2-ton installations where an 80% AFUE furnace fits the plan
Best for Comfort
Goodman 2.5-Ton Two-Stage Gas Dual-Fuel System
- 2.5-ton, 14.5 SEER2 matched cooling system
- 60,000 BTU/h input, two-stage furnace at 96% AFUE
- Horizontal cased coil with factory TXV
Best For: Professionally designed horizontal-coil installations needing two-stage gas heat
Compact 40K Gas Backup
Goodman 1.5-Ton 80% AFUE Dual-Fuel System
- 1.5-ton matched system rated 14.5 SEER2
- 40,000 BTU/h, 80% AFUE furnace
- Single-stage heat pump and gas heat
Best For: Professionally sized 1.5-ton installations needing 40,000 BTU/h gas input
Higher-Capacity Cooling
Goodman 2-Ton 80% AFUE Dual-Fuel System
- 2-ton matched system rated 14.5 SEER2
- 60,000 BTU/h, 80% AFUE furnace
- Two-stage gas heat; single-stage heat pump
Best For: Professionally sized 2-ton installations needing two-stage gas heat
High-AFUE Gas Backup
Goodman 1.5-Ton 96% AFUE Dual-Fuel System
- 1.5-ton matched system rated 14.5 SEER2
- 60,000 BTU/h, 96% AFUE furnace
- Two-stage gas heat; single-stage heat pump
Best For: Professionally sized 1.5-ton installations seeking a 96% AFUE furnace
High-Efficiency Gas Pick – Goodman 2-Ton 96% AFUE Dual-Fuel System
Among dual fuel furnace systems, this matched Goodman package pairs a 2-ton R-32 heat pump with a 60,000 BTU/h input gas furnace. Its 14.5 SEER2 cooling rating applies to the complete matched combination, while the furnace is rated 96% AFUE.
Best For: Buyers whose professionally sized installation calls for 2-ton cooling, upflow/downflow coil placement, and two-stage gas heat.
Pros:
- Two-stage, 96% AFUE furnace with a multi-speed ECM blower.
- Matched cased coil includes a factory-installed TXV.
- Heat pump provides both cooling and electric heating.
Cons:
- Single-stage heat-pump compressor runs at full output when called.
- Furnace cannot be sold in Colorado or California’s special emissions regulation districts.
- Thermostat, line set, labor, and field accessories are not included.
This is the strongest gas-efficiency choice in this group, provided the capacity, local sales rules, and installation requirements fit the project.
3-Ton Balanced Pick – Goodman 15.2 SEER2 80,000 BTU Dual-Fuel System
For buyers comparing 3-ton dual fuel furnace systems, this Goodman combination pairs an R-32 heat pump and cased coil with an 80,000 BTU/h input gas furnace. The complete matched system is rated 15.2 SEER2 for cooling; the furnace is rated 80% AFUE.
Best For: Professionally sized 3-ton projects that call for an 80,000 BTU/h input furnace and an upflow/downflow coil.
Pros:
- Matched combination carries a 15.2 SEER2 cooling rating.
- Heat pump handles both cooling and heat-pump heating.
- All-aluminum cased coil has a factory-installed TXV.
Cons:
- Single-stage compressor and single-stage gas heat offer no staged output.
- Furnace is not for sale in Colorado.
- Thermostat, line set, labor, and field accessories are excluded.
Choose it on the basis of a contractor’s load calculation and installation plan, not the 3-ton designation alone; the 15.2 SEER2 rating belongs to this specific matched combination.
Horizontal-Coil Pick – Goodman 2-Ton 92% AFUE Dual-Fuel System
This option stands out among the listed dual fuel furnace systems for its horizontal cased coil. It matches a 2-ton R-32 heat pump and coil with a 60,000 BTU/h input furnace; the full combination is rated 14.5 SEER2 for cooling, and the furnace is rated 92% AFUE.
Best For: Professionally sized 2-ton installations that require a horizontal coil and single-stage gas heat.
Pros:
- Horizontal all-aluminum coil includes a factory-installed TXV.
- 92% AFUE furnace has a multi-speed ECM blower.
- Heat pump supplies central cooling and heat-pump heating.
Cons:
- Compressor and gas heating are both single-stage.
- Furnace cannot be sold in Colorado or California’s special emissions regulation districts.
- Thermostat, line set, labor, and field accessories are not included.
The horizontal coil is the deciding feature here: confirm cabinet orientation, capacity, and code compliance with the installer before selecting the package.
Higher Gas-Input Pick – Goodman 3-Ton 100,000 BTU Dual-Fuel System
If a load calculation calls for greater gas-furnace input, this entry among dual fuel furnace systems combines a 3-ton R-32 heat pump with a 100,000 BTU/h input furnace. The matched package is rated 15.2 SEER2 for cooling, and its furnace is rated 80% AFUE.
Best For: Professionally sized 3-ton projects that specifically call for a 100,000 BTU/h input furnace and upflow/downflow coil placement.
Pros:
- Highest stated furnace input of these four packages at 100,000 BTU/h.
- Matched system carries a 15.2 SEER2 cooling rating.
- Cased all-aluminum coil includes a factory-installed TXV.
Cons:
- Single-stage compressor and furnace do not provide staged output.
- Furnace is not for sale in Colorado.
- Thermostat, line set, labor, and field accessories are excluded.
The larger gas-input rating is useful only when the home’s heating load and installation support it; professional sizing matters more than choosing the biggest furnace.
High-Output Gas Backup – Goodman 2.5-Ton 15.2 SEER2 Dual-Fuel System
Among dual fuel furnace systems, this matched Goodman package pairs a 2.5-ton R-32 heat pump with an 80,000 BTU/h input gas furnace. Its 15.2 SEER2 cooling rating applies to the complete matched combination, while the furnace is rated at 96% AFUE.
Best For: Homes professionally sized for 2.5 tons of cooling and an 80,000 BTU/h input, single-stage gas furnace.
Pros:
- Matched heat pump, upflow/downflow cased coil, and gas furnace.
- 96% AFUE furnace with a multi-speed ECM blower.
- Factory-installed TXV in the R-32 coil.
Cons:
- Single-stage compressor and gas heat offer no staged output.
- Not for sale in Colorado or California special emissions regulation districts; thermostat, line set, labor, and field accessories are excluded.
Choose this package for its specified cooling match and higher gas input, not by tonnage alone. Have an installer verify the heating load, ductwork, venting, controls, and local R-32 requirements before ordering.
Compact 2-Ton Match – Goodman 15.2 SEER2 Dual-Fuel System
This is the 2-ton option among these dual fuel furnace systems: a matched R-32 heat pump, cased coil, and 60,000 BTU/h input gas furnace. The complete combination is rated at 15.2 SEER2 for cooling; the furnace carries an 80% AFUE rating.
Best For: Homes professionally sized for 2-ton cooling and a 60,000 BTU/h input, 80% AFUE gas furnace.
Pros:
- Matched heat pump, upflow/downflow coil, and gas furnace.
- Factory-installed TXV and all-aluminum R-32 coil.
- Multi-speed ECM furnace blower.
Cons:
- 80% AFUE is lower than the 96% AFUE furnace options in this roundup.
- Not for sale in Colorado; thermostat, line set, labor, and field accessories are excluded.
Its smaller cooling capacity distinguishes it from the two 2.5-ton packages, but proper load calculations still matter. Confirm ductwork, gas service, venting, controls, and local R-32 code compliance with a professional installer.
Best for Comfort – Goodman 2.5-Ton Two-Stage Gas Dual-Fuel System
For buyers comparing dual fuel furnace systems with a horizontal indoor coil, this Goodman package combines a 2.5-ton R-32 heat pump with a two-stage, 60,000 BTU/h input gas furnace. Its matched cooling rating is 14.5 SEER2, and the furnace is rated at 96% AFUE.
Best For: Professionally designed installations calling for a horizontal coil, 2.5-ton cooling, and two-stage gas heating.
Pros:
- Two-stage gas furnace with a multi-speed ECM blower.
- 96% AFUE furnace rating.
- Matched horizontal R-32 coil with factory-installed TXV.
Cons:
- 14.5 SEER2 matched cooling rating is below the 15.2 SEER2 packages listed here.
- Heat-pump compressor is single-stage; furnace is not for sale in Colorado or California special emissions regulation districts.
The horizontal coil and two-stage gas heat are the reasons to consider this configuration. Have an installer check the required orientation, heating and cooling loads, venting, controls, and R-32 compliance; labor, thermostat, line set, and field accessories are not included.
Compact 40K Gas Backup – Goodman 1.5-Ton 80% AFUE Dual-Fuel System
Among dual fuel furnace systems, this matched Goodman package pairs a 1.5-ton R-32 heat pump with a 40,000 BTU/h gas furnace. Its 14.5 SEER2 cooling rating applies to the complete matched combination, not to an individual component.
Best For: Homes professionally sized for 1.5-ton cooling and a 40,000 BTU/h, single-stage gas furnace.
Pros:
- Includes the heat pump, cased indoor coil, and gas furnace as a matched package.
- Factory-installed TXV in the all-aluminum indoor coil adjusts refrigerant flow.
- Multi-speed ECM furnace blower; eligible for a 10-year parts limited warranty when applicable requirements are met.
Cons:
- Single-stage compressor and single-stage gas heating do not offer staged output.
- Thermostat, line set, labor, and field accessories are not included; the furnace is not for sale in Colorado.
This is the smaller gas-input choice of the three. Have a qualified installer verify sizing, controls, venting, and R-32 code requirements before ordering.
Higher-Capacity Cooling – Goodman 2-Ton 80% AFUE Dual-Fuel System
For buyers comparing dual fuel furnace systems with more cooling capacity, this Goodman package combines a 2-ton R-32 heat pump, matched coil, and 60,000 BTU/h gas furnace. The 14.5 SEER2 rating belongs to the matched combination.
Best For: Installations professionally sized for 2-ton cooling and a two-stage, 60,000 BTU/h gas furnace.
Pros:
- Matched heat pump, cased coil, and furnace are supplied together.
- Two-stage gas heating provides more than one furnace output stage.
- Indoor coil has a factory-installed TXV and all-aluminum construction.
Cons:
- The heat-pump compressor is single-stage, operating at full output when called.
- Not for sale in Colorado or California special emissions regulation districts; thermostat, line set, labor, and field accessories are excluded.
Choose this package for its specified capacity and two-stage gas heating, not on tonnage alone. Professional sizing and checks of the gas, electrical, venting, and R-32 installation requirements remain essential.
High-AFUE Gas Backup – Goodman 1.5-Ton 96% AFUE Dual-Fuel System
This entry in the dual fuel furnace systems lineup pairs a 1.5-ton R-32 heat pump with a 60,000 BTU/h, 96% AFUE gas furnace. Its 14.5 SEER2 cooling rating applies to the complete matched combination, while the AFUE rating describes the furnace.
Best For: Installations professionally sized for 1.5-ton cooling and 60,000 BTU/h gas input where a 96% AFUE furnace is desired.
Pros:
- Includes the matched heat pump, cased coil, and gas furnace.
- 96% AFUE furnace offers two-stage heating and a multi-speed ECM blower.
- All-aluminum indoor coil includes a factory-installed TXV.
Cons:
- The heat-pump compressor is single-stage rather than staged.
- Not for sale in Colorado or California special emissions regulation districts; thermostat, line set, labor, and field accessories are excluded.
The higher furnace AFUE and two-stage gas operation distinguish this 1.5-ton package. Confirm the heating and cooling loads independently, along with venting, condensate handling, and R-32 code compliance, before purchase.
How We Picked These Dual Fuel Furnace Systems
We compared the 10 listed Goodman packages using their published heat-pump capacity, SEER2 rating, furnace input rating, AFUE rating, Low NOx designation, and R-32 refrigerant. The selection covers 1.5- to 3-ton heat pumps, 40,000- to 100,000-BTU furnace inputs, and 80%, 92%, or 96% AFUE options. This is a comparison of listed specifications, not a claim that we tested the equipment or verified installed performance.
Quick Comparison
For a smaller cooling load, start by discussing the 1.5-ton packages with your installer; they differ substantially in furnace input and efficiency. The 2-ton group offers 60,000-BTU furnace options across 80%, 92%, and 96% AFUE. The 2.5-ton packages pair larger cooling capacity with 96% AFUE furnaces and either 60,000- or 80,000-BTU input. The 3-ton options list 80% AFUE furnaces with 80,000- or 100,000-BTU input. Listed SEER2 values are 14.5 or 15.2, so compare exact matched-system documentation rather than assuming one component determines the final rating.
Key Buying Factors for Dual Fuel Furnace Systems
Size Heating and Cooling Separately
Heat-pump tonnage describes nominal cooling capacity, while furnace BTU input describes fuel consumption at its rated firing rate—not the heat delivered into your ducts. A contractor should perform a heating and cooling load calculation and check duct airflow before recommending either size. Bigger equipment can cycle poorly and may not solve comfort problems.
Match Efficiency to Your Home and Climate
AFUE estimates the share of furnace fuel converted to usable heat under standardized conditions; higher AFUE can matter more when the furnace runs often. SEER2 describes seasonal cooling efficiency, but it does not by itself tell you how efficiently the heat pump heats in cold weather. Ask for the specific system’s heating-performance data and an estimated operating-cost comparison using local electricity and gas rates.
Confirm Installation Details
Higher-AFUE furnaces may require different venting and condensate drainage than an 80% AFUE replacement. Confirm that the indoor coil, outdoor unit, furnace, and dual-fuel controls are approved as a matched combination. Discuss the temperature or cost-based switchover strategy with your installer. Check local Low NOx rules, R-32 handling requirements, permits, and available rebates before ordering; eligibility can depend on the exact model combination.
Who Should Buy Which Dual Fuel Furnace Systems?
Choose a 1.5- or 2-ton candidate only if your calculated cooling load supports it, then select furnace input based on the heating load. Consider a 2.5-ton package when the home needs that cooling capacity and a 96% AFUE furnace suits its installation. Look at the 3-ton, 80% AFUE options when the load calculation calls for larger cooling capacity and the existing venting or project budget favors a non-condensing furnace. If furnace runtime is high, compare the 92% and 96% AFUE choices against installation costs—not just equipment prices. In every case, get a written quote for the complete matched system, controls, and required duct or vent changes.